Freezstop Regular (FSR)
Freezstop Regular is an industrial/commercial grade self-regulating heating cable that can be used for freeze protection or temperature maintenance of pipework and vessels in the construction and refrigeration industries. It can be cut-to-length on site to match exact piping lengths without any complicated design considerations. Freezstop Regular is approved for use in non-hazardous, and hazardous areas to world wide standards. Its self-regulating characteristics improve safety and reliability. Freezstop Regular will not overheat or burnout, even when overlapped upon itself. Its power output self-regulates in response to the pipe temperature. Freezstop Regular is available with a corrosion resistant thermoplastic outer jacket (FSR-CT). When greater corrosion resistance is required a fluoropolymer outer jacket (FSR-CF) can be supplied. |
Example of Applications
- Freeze protection of pipework & vessels
- Process temperature maintenance
- Refrigeration Industries
Benefits
- Can be cut to length
- Output self-regulates in response to pipe temperature
- No overheating or burnout
- Inherently Temperature Safe
The installation of Freezstop Regular is quick and simple and requires no special skills or tools. Termination, splicing and power connection components are all provided in convenient kits.
-
Product Specification - Maximum Withstand Temperature 85°C (185°F)
Freezstop Regular is available in 10, 17, 25, 31 and 40 W/m outputs as illustrated on the graph to the right. The graph shows the nominal power output at 230V when installed on insulated metal pipes.
Maximum Continuous Exposure
Temperature (Power ON)
85°C (185°F)
Maximum Permissable Exposure
Temperature (Power OFF)
85°C (185°F)
Minimum Operating Temperature
-40ºC (-40ºF)
Temperature Classification
Up to 31 W/m T6 (85°C/185°F)
40 W/m or 277V T4 (135°C/275°F)Power Supply
12 - 277 VAC
Cable Dimensions FSS-CF
12.95 x 5.95mm +/- 0.5mm
Minimum Installation Temperature
-40°C (-40°F)
Minimum Bending Radius
FSR-CT 35mm
FSR-CF 35mmWeight kg/100m
FSR-CT - 12.9 kg
FSR-CF - 14.8 kgMaximum Resistance of Protective Braiding
18.2 Ohm/km
Cable Gland Thread Size
M20
Maximum Circuit Length (m) for various circuit breaker sizes
Product
ReferenceStart-Up
Termperature (°C)230v
10A
16A
20A
32A
10FSR
10
136
198
198
198
0
122
188
188
188
-20
108
174
176
176
-40
96
154
166
166
17FSR
10
92
148
152
152
0
84
134
144
144
-20
74
118
136
136
-40
66
106
128
128
25FSR
10
74
118
124
124
0
68
108
120
120
-20
60
94
112
112
-40
52
84
106
106
31FSR
10
58
92
112
112
0
52
84
104
106
-20
46
74
92
100
-40
42
66
82
94
40FSR
10
46
74
92
98
0
42
66
84
94
-20
36
58
74
88
-40
32
52
66
84
For use with Type C circuit breakers to IEC 60898
-
Approvals & Certifications
FSR
19ATEX3378FSR
CML 19.0121Self Reg. 01383/22
FSR TAE0000272
FSR
19.1555UFSR
FSR
Chinese -
Documents of Conformity
FSR
EU DoC