Longline (HTP3F) is available in 10, 15, and 23 W/m outputs. |
Maximum Withstand Temperature ( Power off ) | 125°C (257°F) |
Minimum Installation Temperature | -40°C (-40°F) |
Power Supply | up to 600V 3-Phase |
Cable Dimensions | HTP3F-CT 25.0 x 7.0mm +/- 0.5mm |
Weight kg/100m | HTP3F-CT - 65.0 kg |
Minimum Bending Radius | 75mm |
Heater Nominal Output (W/m) | HTP3F | HTP3F-C | HTP3F-CT |
---|---|---|---|
10 | 112 | 109 | 100 |
15 | 94 | 95 | 85 |
23 | 78 | 80 | 70 |
Surface temperature limits in acordance with EN50014 |