The surface of the heating cable must not exceed the maximum temperature of the constructional materials or the Temperature Classification if installed in a hazardous area. This is ensured by limiting the pipe or workpiece temperature to a safe level either by design calculation or by means of temperatue control devices.
Tanks and Vessels


The Problem |
Heat tracing is applied to tanks and vessels to ensure that products are stored at the correct temperature. Usually the system is designed to compensate for losses through the thermal insulation although there are some cases where there is a positive heat input to raise the temperature of the vessel under defined conditions. The thermal insulation is the first line of defence against unknown, and often unquantifiable, losses from a bare surface. | |  |
How heat is lost from a tank? |
There are three ways to lose heat from a tank or vessel. |
| - by conduction through the structure and any thermal insulation layer. Heat flows from the contained medium through the walls, floor and roof and fittings attached to the tank and is dissipated to the surroundings by.......
- convection effects that may be natural convection, where there is no wind movement, or forced convection, where there is movement of the surrounding atmosphere. This is particularly noticeable outdoors where the convective losses can be quite severe at higher wind speeds. The remaining mechanism for losing heat is........
- radiation. All bodies radiate heat if they are hotter than their surroundings. Therefore, the outer cladding of a tank or vessel will lose heat by radiation to a colder surrounding atmosphere. This effect increases with temperature and is independant of any convective losses. This effect is most noticeable at surface temperatures above 100°C.
| |
The Solution |
Once the heat losses have been calculated you can determine the amount of cable required based on the heat losses and size of the tank. If the cicuit lenghs are less than 200m then parallel resistance self regulating (eg.Freezstop Regular) or constant power heating cables (eg. MiniTracer) are chosen which can be cut to length when required at site. When longer circuit lengths are required, series resistance cables should also be considered (eg. Longline).as these can normally be installed in a single circuit or supply point. |  Self-Regulating Cables Freezstop Super (FSS-CF) |  Constant Wattage Cables MiniTracer (MTFJ) |  Series Resistance Cables Longline (HTS3F-CS) | |

Product and Application Datasheets
Latest News
-
Heat Trace - 'going the distance'
More... | 27 July 2015
-
Heat Trace Ltd November new starters
More... | 21 December 2017
-
National Apprenticeship Awards 2019
More... | 13 December 2019
-
BEWARE - COUNTERFEITERS
More... | 15 June 2010
-
Heat Trace Ltd - July - September new starters
More... | 27 September 2017
-
2017 New starters
More... | 22 June 2017