MAL Mineral Insulated Cable
The MAL range of alloy 825 sheathed Mineral Insulated (MI) heating cable has been developed to meet the specific need for a cable having a high temperature capability and electrical resistance values needed for long circuit lengths. To meet the requirement, Heat Trace has combined an alloy 825 sheath with heating conductors to enable an operating temperature of 800ºC with resistance values from 2.1Ω/km up to 36100Ω/km per conductor. MI cables have excellent mechanical strength and are intrinsically very resistant to corrosion. They are series resistance heaters which must be designed to provide the required heat output.
Example of Applications
- Freeze protection of high exposure pipelines (e.g. steam manifolds)
- Temperature maintenance of pipelines
Benefits
- Circuit lengths up to 5 - 6km
- Suitable for single or 3 phase applications
- Metal jacket for increased mechanical strength and fire resistance
Product Specification - maximum withstand temperature MCU 250°C (482°F) or MHC 90°C (194°F)
Mineral Insulated Cable (MAL) is available up to 300 W/m outputs. |
Maximum Withstand Temperature | 800°C (1472°F) |
Minimum Installation Temperature | -80°C (-112°F) |
Minimum Operating Temperature | -80°C (-112°F) |
Rated Voltage | up to 600V |
Cable Dimensions | see data sheet |
Minimum Bending Radius | see data sheet |
Maximum Workpiece Temperatures (°C)
Please contact Heat Trace Ltd for details of maximum workpiece temperatures. |
|---|
Accreditations

MAL18ATEX3391